The fiber optic switch AGS14 is a non-mechanical designed fiber optic device based on the Faraday effect with Bi-refringent crystal and micro-optical components. Without moving parts in the design, the switch can meet the high requirement on reliability, durability and high switching speed.
High Speed
Non-Mechanical
High Stability & Reliability
Fiber Optical Sensing
Switching
Latching
Signal Monitoring
1x4 | Min | Typical | Max | Unit |
Operation Wavelength | 1500 | 1550 | 1600 | nm |
Insertion Loss | 1.5 | 1.1 | 1.5 | dB |
PDL | 0.1 | 0.2 | dB | |
ER(PM version) | 18 | dB | ||
Cross Talk | 32 | 50 | 32 | dB |
PMD | 0.1 | 0.2 | ps | |
Return Loss | 50 | dB | ||
Durability | 1011 | cycle | ||
Operating Temperature | -5 | 70 | ℃ | |
Optical Power | 500 | mW | ||
Storage Temperature | -40 | 85 | ℃ | |
Switch Type | Latching | |||
Fiber Type | SMF28 / PM1550 | |||
Switch Time | 0.8 | ms | ||
Power Input | DC 12V | |||
Dimension | 152mm*142mm*50mm |
Electrical characteristics: Conforms to the EIA-574 standard (EIA-232 (RS-232), 9-pin) Baud rate: 2400, 9600, 57600, 115200, 230400
Start bit: 1 bit, fixed Data length: 8 bit, fixed
Parity: Odd, Even, or None Stop bit: 1 bit(default)
Connector: DELC-J9PAF-13L6 (JAE or equivalent) Flow control: None
UART bit formats are listed in the following table:
Parity | UART frame |
None | | Start bit | 8-bit data | Stop bit | |
Odd/Even | | Start bit | 8-bit data | Parity bit | Stop bit | |
Electromechanical specifications: Conforms to IEEE802.3 Transmission method: 10BaseT/100BaseTX Ethernet Communication protocol: TCP/IP
Connector type: RJ45
Port number used: 8080 (fixed)
Visit the website http://192.168.1.100/, 192.168.1.100 is a device IP address. The default network information is on the nameplate attached to the device.
Note: Visit configuration website will increase the switch time when the AGS14 is working at switch mode.
The Ethernet port just supports static IP mode, please avoid conflict with other network devices in the same subnet. If the device has been set to the wrong IP and can`t be accessed any more,push the Restore Button for 6 seconds to restore the default settings. When push down the Restore Button, the LED will twinkle until restore succeed.
A complete frame contains 2 bytes: fixed start byte and command byte. Start byte Command byte
0xF0(Fixed) 1-byte data
Once the client transmits the command, it needs to wait for the device to reply.
Function | Transmit frame (hexadecimal) | Reply frame (hexadecimal) |
Say hello, use for test connection, the device will do nothing | 0xF000 | 0xF000 |
Switch to channel 1 | 0xF001 | 0xF001 |
Switch to channel 2 | 0xF002 | 0xF002 |
Switch to channel 3 | 0xF003 | 0xF003 |
Switch to channel 4 | 0xF004 | 0xF004 |